Mechanische Lebensdauer: min. 1.000.000 Zyklen.
Isolationswiderstand: min. 100 MΩ.
Spannungsfestigkeit: 1000 V AC für 60 ± 5 Sekunden
Gehäusematerial: UL 94V0 Thermoplast
Kontaktwiderstand: max. 50 mΩ Anfangswiderstand
| Modell | Temperatur | Kontaktart | Bewertung | UL1054 Elife | IEC61058 Elife | IEC60335 Elife | UL858 Elife |
| L41 | 40 T 85 | A1 | 0,1 A 125/250 V AC | 100000 | 50000 | ||
| L42 | 40 T 85 | A1 | 5,0 A 125/250 V AC | 100000 | |||
| 5(1)A 250VAC | 50000 | ||||||
| L50 | 40 T 105 | A2 | 0,1 A 125/250 V AC | 100000 | 100000 | ||
| 0,1 A 30 V DC | |||||||
| L51 | 40 T 105 | A1 | 0,1 A 125/250 V AC | 100000 | 50000 | ||
| 0,1 A 30 V DC | |||||||
| L52 | 40T125 | A1 | 5,0 A 125/250 V AC | 100000 | |||
| 5(1)A 250VAC | 50000 | ||||||
| L53 | 40 T 85 | A1 | 0,1 A 125/250 V AC | 50000 | Ja | ||
| L54 | 40T125 | A1 | 5,0 A 125/250 V AC | 50000 | Ja | ||
| L61 | 40T150 | A1 | 0,1 A 125/250 V AC | 100000 | 6000+94000 | ||
| 2A 125/250VAC | |||||||
| 0,1 A 30 V DC | 6000 | ||||||
| A2 | 0,1 A 125/250 V AC | 100000 | |||||
| 0,1 A 30 V DC | 100000 | ||||||
| L62 | 40T150 | A1 | 5A 125/250VAC | 100000 | 6000+94000 | ||
| L71 | 40T200 | A1 | 0,1 A 125/250 V AC | 6000 | |||
| 0,1 A 30 V DC | 6000 | ||||||
| 1A 30VDC | 6000 | ||||||
| L72 | 40T200 | A1 | 5A 125/250VAC | 100000 | |||
| 0,1 A 30 V DC | 6000 | ||||||
| 1A 30VDC | 6000 | ||||||
| L91 | 40T220 | A1 | 0,1 A 125/250 V AC | 100000 | 6000+94000 | ||
| L92 | 40T220 | A1 | 5A 125/250VAC | 100000 | 6000+94000 |